A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. The web server accepts the OPTIONS method. An attacker could potentially use this information to carry out other attacks. The affected products and versions are as follows: FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. The web server accepts access by IP address. When a worm that randomly searches for IP addresses intrudes into the network, it could potentially be attacked by the worm. The affected products and versions are as follows: FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
Insecure default settings have been found in recorder products provided by Yokogawa Electric Corporation. The default setting of the authentication function is disabled on the affected products. Therefore, when connected to a network with default settings, anyone can access all functions related to settings and operations. As a result, an attacker can illegally manipulate and configure important data such as measured values and settings. This issue affects GX10 / GX20 / GP10 / GP20 Paperless Recorders: R5.04.01 or earlier; GM Data Acquisition System: R5.05.01 or earlier; DX1000 / DX2000 / DX1000N Paperless Recorders: R4.21 or earlier; FX1000 Paperless Recorders: R1.31 or earlier; μR10000 / μR20000 Chart Recorders: R1.51 or earlier; MW100 Data Acquisition Units: All versions; DX1000T / DX2000T Paperless Recorders: All versions; CX1000 / CX2000 Paperless Recorders: All versions.
The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00
The following Yokogawa Electric products do not change the passwords of the internal Windows accounts from the initial configuration: CENTUM VP versions from R5.01.00 to R5.04.20 and versions from R6.01.00 to R6.08.0, Exaopc versions from R3.72.00 to R3.79.00.
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to execute arbitrary code via a crafted packet.
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (process outage) via a crafted packet.
Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless Device OPC Server R2.01.02 and earlier, PRM R3.12.00 and earlier, STARDOM VDS R7.30.01 and earlier, STARDOM OPC Server for Windows R3.40 and earlier, FAST/TOOLS R10.01 and earlier, B/M9000CS R5.05.01 and earlier, B/M9000 VP R7.03.04 and earlier, and FieldMate R1.01 or R1.02 allows remote attackers to cause a denial of service (network-communications outage) via a crafted packet.
License Manager Service of YOKOGAWA products (CENTUM VP (R5.01.00 - R6.06.00), CENTUM VP Entry Class (R5.01.00 - R6.06.00), ProSafe-RS (R3.01.00 - R4.04.00), PRM (R4.01.00 - R4.02.00), B/M9000 VP(R7.01.01 - R8.02.03)) allows remote attackers to bypass access restriction to send malicious files to the PC where License Manager Service runs via unspecified vectors.
Buffer overflow in the license management function of YOKOGAWA products (iDefine for ProSafe-RS R1.16.3 and earlier, STARDOM VDS R7.50 and earlier, STARDOM FCN/FCJ Simulator R4.20 and earlier, ASTPLANNER R15.01 and earlier, TriFellows V5.04 and earlier) allows remote attackers to stop the license management function or execute an arbitrary program via unspecified vectors.
Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web application improperly protects credentials which could allow an attacker to obtain credentials for remote access to controllers.
Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU controllers R4.02 and prior, and FCN-500 controllers R4.02 and prior utilize hard-coded credentials that could allow an attacker to gain unauthorized administrative access to the device, which could result in remote code execution.
A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. This product does not properly encode URLs. An attacker could tamper with web pages or execute malicious scripts. The affected products and versions are as follows: FAST/TOOLS (Packages: RVSVRN, UNSVRN, HMIWEB, FTEES, HMIMOB) R9.01 to R10.04
| CVE ID ⇅ | Severity ↓ | Description | |
|---|---|---|---|
| CVE-2025-66603 | CRITICAL | A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. The web s… | › |
| CVE-2025-66602 | CRITICAL | A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. The web s… | › |
| CVE-2025-1863 | CRITICAL | Insecure default settings have been found in recorder products provided by Yokogawa Electric Corpora… | › |
| CVE-2022-23402 | CRITICAL | The following Yokogawa Electric products hard-code the password for CAMS server applications: CENTUM… | › |
| CVE-2022-21194 | CRITICAL | The following Yokogawa Electric products do not change the passwords of the internal Windows account… | › |
| CVE-2015-5628 | CRITICAL | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50… | › |
| CVE-2015-5627 | CRITICAL | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50… | › |
| CVE-2015-5626 | CRITICAL | Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50… | › |
| CVE-2019-5909 | CRITICAL | License Manager Service of YOKOGAWA products (CENTUM VP (R5.01.00 - R6.06.00), CENTUM VP Entry Class… | › |
| CVE-2018-0651 | CRITICAL | Buffer overflow in the license management function of YOKOGAWA products (iDefine for ProSafe-RS R1.1… | › |
| CVE-2018-17900 | CRITICAL | Yokogawa STARDOM Controllers FCJ, FCN-100, FCN-RTU, FCN-500, All versions R4.10 and prior, The web a… | › |
| CVE-2018-10592 | CRITICAL | Yokogawa STARDOM FCJ controllers R4.02 and prior, FCN-100 controllers R4.02 and prior, FCN-RTU contr… | › |
| CVE-2025-66606 | CRITICAL | A vulnerability has been found in FAST/TOOLS provided by Yokogawa Electric Corporation. This prod… | › |