A vulnerability (CWE-428) has been identified in the Uninterruptible Power Supply (UPS) management application provided by OMRON SOCIAL SOLUTIONS Co., Ltd., where the executable file paths of Windows services are not enclosed in quotation marks. If the installation folder path of this product contains spaces, there is a possibility that unauthorized files may be executed under the service privileges by using paths containing spaces.
Sysmac Studio provided by OMRON Corporation contains an incorrect authorization vulnerability. If this vulnerability is exploited, an attacker may access the program which is protected by Data Protection function.
Improper restriction of XML external entity reference (XXE) vulnerability exists in OMRON CX-Motion Pro 1.4.6.013 and earlier. If a user opens a specially crafted project file created by an attacker, sensitive information in the file system where CX-Motion Pro is installed may be disclosed.
In Omron CX-Supervisor Versions 3.30 and prior, processing a malformed packet by a certain executable may cause an untrusted pointer dereference vulnerability.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a double free vulnerability.
In Omron CX-Supervisor Versions 3.30 and prior, use after free vulnerabilities can be exploited when CX Supervisor parses a specially crafted project file.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a heap-based buffer overflow.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause an out of bounds vulnerability.
In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can be exploited when CX Supervisor indirectly calls an initialized pointer when parsing malformed packets.
In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a stack-based buffer overflow.
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.
Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to hijack the authentication of unspecified victims via unknown vectors.
The OMRON OpenWnn application before 1.3.6 for Android uses weak permissions for unspecified files, which allows attackers to obtain sensitive information via an application that accesses the local filesystem.
Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and NS15 HMI terminals 8.1xx through 8.68x allows remote authenticated users to inject arbitrary web script or HTML via crafted data.
| CVE ID ⇅ | Severity ↓ | Description | |
|---|---|---|---|
| CVE-2025-9818 | MEDIUM | A vulnerability (CWE-428) has been identified in the Uninterruptible Power Supply (UPS) management a… | › |
| CVE-2024-49501 | MEDIUM | Sysmac Studio provided by OMRON Corporation contains an incorrect authorization vulnerability. If th… | › |
| CVE-2023-22322 | MEDIUM | Improper restriction of XML external entity reference (XXE) vulnerability exists in OMRON CX-Motion … | › |
| CVE-2018-7525 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, processing a malformed packet by a certain executabl… | › |
| CVE-2018-7523 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a double f… | › |
| CVE-2018-7521 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, use after free vulnerabilities can be exploited when… | › |
| CVE-2018-7519 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a heap-bas… | › |
| CVE-2018-7517 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause an out of … | › |
| CVE-2018-7515 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, access of uninitialized pointer vulnerabilities can … | › |
| CVE-2018-7513 | MEDIUM | In Omron CX-Supervisor Versions 3.30 and prior, parsing malformed project files may cause a stack-ba… | › |
| CVE-2015-0987 | MEDIUM | Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 … | › |
| CVE-2014-2369 | MEDIUM | Cross-site request forgery (CSRF) vulnerability in the web application on Omron NS5, NS8, NS10, NS12… | › |
| CVE-2013-2301 | MEDIUM | The OMRON OpenWnn application before 1.3.6 for Android uses weak permissions for unspecified files, … | › |
| CVE-2014-2370 | MEDIUM | Cross-site scripting (XSS) vulnerability in the web application on Omron NS5, NS8, NS10, NS12, and N… | › |