Beckhoff IPC Diagnostics before 1.8 does not properly restrict access to functions in /config, which allows remote attackers to cause a denial of service (reboot or shutdown), create arbitrary users, or possibly have unspecified other impact via a crafted request, as demonstrated by a beckhoff.com:service:cxconfig:1#Write SOAP action to /upnpisapi.
Kernel drivers in Beckhoff TwinCAT 3.1 Build 4022.4, TwinCAT 2.11 R3 2259, and TwinCAT 3.1 lack proper validation of user-supplied pointer values. An attacker who is able to execute code on the target may be able to exploit this vulnerability to obtain SYSTEM privileges.
A Denial-of-Service vulnerability exists in BECKHOFF Ethernet TCP/IP Bus Coupler BK9000. After an attack has occurred, the device's functionality can be restored by rebooting.
When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controller could be reached by sending a malformed UDP packet to the device. This issue affects TwinCAT 2 version 2304 (and prior) and TwinCAT 3.1 version 4204.0 (and prior).
The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinCAT. If the directory does not exist it and further subdirectories are created with permissions which allow every local user to modify the content. The default installation registers TcSysUI.exe for automatic execution upon log in of a user. If a less privileged user has a local account he or she can replace TcSysUI.exe. It will be executed automatically by another user during login. This is also true for users with administrative access. Consequently, a less privileged user can trick a higher privileged user into executing code he or she modified this way. By default Beckhoff’s IPCs are shipped with TwinCAT software installed this way and with just a single local user configured. Thus the vulnerability exists if further less privileged users have been added.
| CVE ID ⇅ | Severity ↓ | Description | |
|---|---|---|---|
| CVE-2015-4051 | HIGH | Beckhoff IPC Diagnostics before 1.8 does not properly restrict access to functions in /config, which… | › |
| CVE-2018-7502 | HIGH | Kernel drivers in Beckhoff TwinCAT 3.1 Build 4022.4, TwinCAT 2.11 R3 2259, and TwinCAT 3.1 lack prop… | › |
| CVE-2020-9464 | HIGH | A Denial-of-Service vulnerability exists in BECKHOFF Ethernet TCP/IP Bus Coupler BK9000. After an at… | › |
| CVE-2019-5637 | HIGH | When Beckhoff TwinCAT is configured to use the Profinet driver, a denial of service of the controlle… | › |
| CVE-2020-12510 | HIGH | The default installation path of the TwinCAT XAR 3.1 software in all versions is underneath C:\TwinC… | › |